Product information

Product Description

Connect the a3000 FC Wireless AC Current Clamp Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter. You ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Clamp Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect app has all the essentials for convenient test and measurement troubleshooting:

Key Features

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:

Key Features

  • True-RMS AC clamp meter
  • Measure up to 400 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function

Specifications

Specification Details
Fluke 3000 FC Series Wireless Multimeter
AC Voltage Range / Resolution:
600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
AC Voltage Accuracy:
45 Hz to 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
mV Range / Resolution 600.0 mV / 0.1 mV
mV Accuracy 0.09% + 2
V Range / Resolution:
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
V Accuracy:
0.09% + 2
0.15% + 2
Range / Resolution 600 / 1
Accuracy Meter beeps at
Range / Resolution:
600.0 / 0.1
6.000 k / 0.001 k
60.00 k / 0.01 k
60.00 k / 0.1 k
600.0 k / 0.001 M
50.00 M / 0.01 M
Accuracy:
0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / Resolution 2.000 V / 0.001 V
Diode test Accuracy 1% + 2
µF Range / Resolution:
1000 nF / 1 nF
10.00 F / 0.01 F
100.0 F / 0.1 F
9999 F1 / 1 F
µF Accuracy:
1.2% + 2
10% typical
mA AC (45 Hz to 1 kHz) Range / Resolution:
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
mA AC (45 Hz to 1 kHz) Accuracy 1.5% + 3
mA DC Range / Resolution:
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
mA DC Accuracy 0.5% + 3
Frequency Range / Resolution:
99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Frequency Accuracy 0.1% + 1
mA Function Overload protection Fused, 44/100 A, 1000 V FAST Fuse
mA Function Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy DC functions The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
MIN/MAX Recording Accuracy AC functions The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type 3 x AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range:
Open air, unobstructed Up to 20m
Obstructed, sheetrock wall Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m
Operating Temperature -10°C to 50°C
Storage Temperature -40°C to 60°C
Temperature coefficient 0.1 X (specified accuracy) / °C ( 28°C)
Relative humidity:
0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Operating Altitude 2,000 m
Storage Altitude 12,000 m
Electromagnetic compatibility - EMI, RFI, EMC, RF
EN 61326 1 2006, EN 61326 2 2:2006
ETSI EN 300 328 V1.7.1 2006, ETSI EN 300 489
V1.8.1 2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID FCC: T68 FDMMBLE IC: 6627A FDMMBLE
Safety compliance:
ANSI / ISA 61010 1 / (82.02.01) 3rd edition
CAN / CSA-C22.2 No 61010-1-12 3rd edition
UL 61010 1 3rd edition
IEC / EN 61010 1 2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Dimensions (L x W x H) 207mm x 93mm x 47.5mm
Weight 0.34kg
Fluke a3000 FC Wireless AC Current Clamp Module
Range 0.5 A to 400.0 A
Resolution 0.1 A
400.0 A Accuracy:
2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100 Hz to 500 Hz)
Inrush Max displayed reading 999.9A
Crest factor (50 Hz / 60 Hz):
3 at 500 A (add 2% for C.F. > 2)
2.5 at 600 A (add 2% for C.F. > 2)
1.42 at 1000 A (add 2% for C.F. > 2)
LCD w/ backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC
Battery type 2 x AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range:
Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1 x (specified accuracy) / °C ( 28°C)
Operating humidity:
90% at 35°C
75% at 40°C
45% at 50°C
Operating Altitude 2,000 m
Storage Altitude 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
Safety rating CAT III 600 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP30
Pollution Degree 2
Jaw opening 34 mm (1.33 in)
Dimensions (L x W x H) 35.5mm x 74.9mm x 203mm
Weight 0.22kg
Part No FLUFLKA3000FCKIT
Barcode 95969724203
Brand Fluke