Product Description
Now compatible with Fluke Connect Mobile App
Fluke's 3000 FC Series Wireless Multimeter puts wireless test tools, not your body, near live electrical panels. Improve safety and efficiency with this tester.
All the facts, right in the field. The Fluke 3000 FC True-rms Wireless Multimeter with the Fluke Connect app and ShareLive video call.
With its precision, reliability and ease of use, the Fluke 3000 FC Wireless Multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600V/ CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to troubleshoot and repair many problems in electrical and electronic systems.
The Fluke 3000 FC gives you True-rms voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 3000 FC provides higher 0.09% basic accuracy, a digital display showing up to three secondary measurements from remote modules, and a bright white backlight.
Work safely near electrical panels while wearing less PPE
The Fluke 3000 FC True-rms Wireless Multimeter and Fluke Connect wireless test tools put tools, not your body, near live electrical panels. It's simple. Just de-energize the cabinet, open the panel while wearing PPE and connect the remote modules, whether they are voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC Wireless Multimeter from a safe distance. You can display the meter measurement, plus readings from up to 3 wireless modules, while reducing the risk of arc flash by separating yourself from hazardous measurement situations.
Better still, the Fluke 3000 FC Series Wireless Multimeter can send measurement data to your smartphone, so you can save and share measurements from the field with your team anytime, from anywhere.
Don't get bogged down while chasing interrelated events
Timing is everything when trying to find the cause of a complex problem. Often you need to make a measurement in one place and see activity on a different part of the system at the same time. We've solved that problem with Fluke Connect - connect your remote modules in one location, then take your measurements up to 20 meters away with the Fluke 3000 FC multimeter. You'll be able to see the interaction between your remote test points on one single screen, in real time. You can even download the data to a PC for further analysis.
Other capabilities of Fluke Connect and the 3000 FC Multimeter.
Key Features
- Add your laptop and go from logging to analysis and diagnosis.
- Record over time using the Fluke Connect wireless modules and monitor circuit load changes for an hour, a shift or a week.
- Use the Fluke Connect wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data.
- Perform for analysis with your PC and share the results using Fluke Cloud storage and ShareLive video call. View data or graphs to get input from team members.
Specifications
| Specification | Details |
|---|---|
| AC Voltage | |
| Range¹ / resolution 600.0 mV / 0.1 mV | |
| 6.000 V / 0.001 V | |
| 60.00 V / 0.01 V | |
| 600.0 V / 0.1 V | |
| 1000 V / 1 V | |
| Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3 | |
| 500 Hz to 1 kHz 2.0% + 3 | |
| 1. AC voltage ranges are specified from 1% of range to 100% of range. | |
| 2. Crest factor of 3 at full scale up to 500 V, decreasing linearly to crest factor 3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3. | |
| 4. Do not exceed 107 V-Hz. | |
| DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |
| mV Range / resolution 600.0 mV / 0.1 mV | |
| Accuracy 0.09% + 2 | |
| V Range / resolution 6.000 V / 0.001 V | |
| 60.00 V / 0.01 V | |
| 600.0 V / 0.1 V | |
| 1000 V / 1 V | |
| Accuracy 0.09% + 2 | |
| 0.15% + 2 | |
| ))) Range / resolution 600 / 1 | |
| Accuracy Meter beeps at | |
| Range / resolution 600.0 / 0.1 | |
| 6.000 k / 0.001 k | |
| 60.00 k / 0.01 k | |
| 60.00 k / 0.1 k | |
| 600.0 k / 0.001 M | |
| 50.00 M / 0.01 M | |
| Accuracy 0.5% + 2 | |
| 0.5% + 1 | |
| 1.5% + 3 | |
| Diode test Range / resolution 2.000 V / 0.001 V | |
| Accuracy 1% + 2 | |
| µF Range / resolution 1000 nF / 1 nF | |
| 10.00 F / 0.01 F | |
| 100.0 F / 0.1 F | |
| 9999 F1 / 1 F | |
| Accuracy 1.2% + 2 | |
| 10% typical | |
| 1. In the 9999 F range for measurements to 1000 F, the measurement accuracy is 1.2% + 2. | |
| AC and DC Current | |
| mA AC | |
| (45 Hz to 1 kHz) Range1 / resolution 60.00 mA / 0.01 mA | |
| 400.0 mA3 / 0.1 mA | |
| Accuracy 1.5% + 3 | |
| mA DC2 Range1 / resolution 60.00 mA / 0.01 mA | |
| 400.0 mA3 / 0.1 mA | |
| Accuracy 0.5% + 3 | |
| 1. All AC current ranges are specified from 5% of range to 100% of range. | |
| 2. Input burden voltage (typical) | 400 mA input 2 mV/mA. |
| 3. 400.0 mA accuracy specified up to 600 mA overload. | |
| Frequency | |
| Range / resolution 99.99 Hz / 0.01 Hz | |
| 999.9 Hz / 0.1 Hz | |
| 9.999 kHz / 0.001 kHz | |
| 99.99 kHz / 0.01 kHz | |
| Accuracy1 0.1% + 1 | |
| 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |
| Input Characteristics | |
| Overload protection 1100 V RMS | |
| Input impedance (nominal) > 10 M | |
| Common mode rejection ratio | |
| (1 k unbalance) > 120 dB at DC, 50 Hz or 60 Hz | |
| Normal mode rejection > 60 dB at 50 Hz or 60 Hz | |
| Overload protection 1100 V RMS | |
| Input impedance (nominal) > 10 M | |
| Common mode rejection ratio | |
| (1 k unbalance) > 60 dB, DC to 60 Hz | |
| Normal mode rejection > 60 dB at 50 Hz or 60 Hz | |
| Overload protection 1100 V RMS | |
| Input impedance (nominal) > 10 M | |
| Common mode rejection ratio | |
| (1 k unbalance) > 120 dB at DC, 50 Hz or 60 Hz | |
| Normal mode rejection > 60 dB at 50 Hz or 60 Hz | |
| Open Circuit Test Voltage | |
| Overload protection 1100 V RMS | |
| Input impedance (nominal) | |
| Full scale voltage to 6 M | |
| Full scale voltage 50 M | |
| Typical short circuit current | |
| Overload protection 1100 V RMS | |
| Input impedance (nominal) | |
| Full scale voltage to 6 M | |
| Full scale voltage 50 M 2.000 V DC | |
| Typical short circuit current | |
| mA Function | |
| Overload protection Fused, 44/100 A, 1000 V FAST Fuse | |
| Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | |
| MIN/MAX Recording Accuracy | |
| DC functions ± 12 counts for changes > 350 mS in duration. | |
| AC functions ± 40 counts for changes > 900 mS in duration. | |
| General Specifications | |
| Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS | |
| fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |
| Display (LCD) Update rate 4/sec | |
| Volts, amps, ohms 6000 counts | |
| Frequency 10,000 counts | |
| Capacitance 1,000 counts | |
| Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 | |
| Battery life 250 hours minimum | |
| RF communications 2.4 GHZ ISM Band | |
| RF communication range Open air, unobstructed Up to 20m | |
| Obstructed, sheetrock wall Up to 6.5m | |
| Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m | |
| Temperature Operating -10°C to 50°C | |
| Storage -40°C to 60°C | |
| Temperature coefficient 0.1 X (specified accuracy) / °C ( 28°C) | |
| Relative humidity 0% to 90% (0°C to 35°C) | |
| 0% to 75% (35°C to 40°C) | |
| 0% to 45% (40°C to 50°C) | |
| Altitude Operating 2,000 m | |
| Storage 12,000 m | |
| Electromagnetic compatibility | |
| EMI, RFI, EMC, RF EN 61326 1 | 2006, EN 61326 2 2:2006 |
| ETSI EN 300 328 V1.7.1 | 2006, ETSI EN 300 489 |
| V1.8.1 | 2008 |
| FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 | |
| FCCID | FCC: T68 FDMMBLE IC: 6627A FDMMBLE |
| Safety compliance ANSI / ISA 61010 1 / (82.02.01) | 3rd edition |
| CAN / CSA-C22.2 No 61010-1-12 | 3rd edition |
| UL 61010 1 | 3rd edition |
| IEC / EN 61010 1 | 2010 |
| Certifications CSA, FCC, CE | |
| Ingress Protection (IP) rating IP54 | |
| Pollution Degree 2 | |
| Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | |
| Weight 340 g (12 oz) | |
| Warranty Three years | |
| Not compatible with Fluke CNX test tools | |
| Part No | FLUFLK3000FC/EDA2 |
| Barcode | 95969799676 |
| Brand | Fluke |
Shipping Policy
Australia-wide Shipping
We ship to addresses across Australia from our network of warehouses and suppliers. A small number of remote locations may not be eligible for delivery. If your address is one of them, we'll let you know promptly.
Your order may be sent from a wholesaler, warehouse or retailer partner, so the packaging may not always show the DEAL FIRST name.
Shipping Costs
Shipping costs are calculated at checkout based on your delivery address and order. You'll see the total before you pay.
Special Orders and Backorders
Special order products refer to items that are not standard inventory or items currently out of stock that must be requested directly from an external supplier. By placing a special order, you acknowledge and agree to the unique processing restrictions outlined below.
Dispatch Timeframes
Unlike standard stocked items which typically ship within 1–2 business days, special order items require additional fulfillment timelines.
- Standard Stock: Dispatched within 1–2 business days.
- Special Orders / Backorders: Expected dispatch ranges between 5 business days to 4 weeks, depending on supplier availability and transit logistics.
Any estimated delivery windows provided at the time of purchase are guidelines and subject to supplier supply chain fluctuations.
Delivery Times
Estimated delivery times, counted from when your order is dispatched:
- Metropolitan areas: 2 to 5 business days
- Regional areas: 2 to 7 business days
- Rural and remote areas: 3 to 10 business days
Tracking
Once your order ships, we'll email you a tracking number where the shipping method supports tracking. Larger orders may arrive in more than one parcel.
Late or Missing Parcels
If your parcel hasn't arrived within the estimated time, or tracking hasn't updated for several days, please contact us with your order number and we'll follow it up with the carrier.
Special Order and Backorder Cancellations
Once a special order or backorder is placed with our supplier, the order cannot be cancelled. Cancellations will only be authorized if the supplying manufacturer permits a penalty-free cancellation to us. If any supplier administrative fees or restocking fees are incurred during a requested cancellation, these costs will be passed on to the customer.
Returns and Refund Policy
At Deal First, we aim to provide you with the best shopping experience. Please review our return and refund policy below:
Consumer Guarantees and Faulty Special Order Items
The restrictions placed on cancellations and change of mind returns do not impact your statutory consumer rights. If a special order item arrives damaged, is structurally faulty, or fails to meet legal consumer standards, you remain fully covered under Australian Consumer Law (ACL) and the manufacturer's operational warranties. Faulty items will be repaired, replaced, or refunded in accordance with your legal rights.
Damaged or Defective Items
If you receive an item that is damaged or defective, we will provide a prepaid shipping label for you to return the product. Please contact us as soon as possible to arrange this.
Non-Damaged Returns
If you wish to return an item for any reason other than damage or defect, you will be responsible for all return shipping costs. The item must be returned within 30 days of receipt, unused, undamaged, and in its original packaging. Returns without original packaging may be refused.
Special Order and Backorder Change of Mind Returns
Our standard return and exchange policies do not apply to custom configurations, non-stocked products, spare parts, or special order items. We do not offer refunds, credits, or exchanges for change of mind on any special order goods. Please ensure all product specifications, sizes, and compatibility requirements are fully verified before finalizing your purchase.
Restocking Fees
Items returned due to buyer’s remorse, incorrect purchase, or changes in preferences (e.g., no longer wanted/needed, found a better price) may incur a restocking fee of up to 20%. This fee also applies to non-warranty returns.
Return Time frame
- Electronics: Must be returned within 15 days of the delivery date.
- All other items: Must be returned within 30 days of the delivery date.
Returns outside these time frames can't be accepted.
Return Authorization
To request one, contact us with your order number. Before returning any item, you must submit a return request and receive a Return Merchandise Authorization (RMA) number. Items sent without an RMA number will not be accepted.
Non-Returnable Items
For health and safety reasons, the following items cannot be returned:
- Grocery items
- Undergarments
- Personal care products (e.g., nappies, opened skincare or cosmetics)
Shipping Damage
If your item arrives damaged due to shipping, please refuse delivery if possible and contact us immediately. If you cannot refuse delivery, retain all packaging materials and notify us so we can process an RMA.
Altered or Incomplete Returns
Items that are altered, modified, missing parts, or not in their original condition may not be eligible for a refund. Please ensure all components are included before returning your item.
Prepaid Shipping Labels
When we provide a prepaid label, you must drop off the item or schedule a pick-up with the carrier within 7 days of receiving the label.
Refund Processing
We will typically issue a refund once the returned item is in transit with the carrier. However, please allow up to 15 days from the shipping date for the return to be processed and your refund to be issued.
Supplier-Specific Returns
Since we work with multiple suppliers, each may have their own return procedures and timelines. We will coordinate with the appropriate supplier to handle your return in a timely manner.
You might also like
Customer reviews
No reviews yet for this product.