{"product_id":"fluke-1732-and-1734-three-phase-electrical-energy-loggers-advanced-flu1734eus","title":"FLUKE 1732 and 1734 Three-Phase Electrical Energy Loggers - Advanced FLU1734EUS","description":"\u003cbody\u003e\r\n\r\n\t\u003ctitle\u003e\u003c\/title\u003e\r\n\r\n\r\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"description\" style=\"\"\u003e\u003cp\u003eThe Fluke 1734 (with WIFI) Three-Phase Electrical Energy loggers introduce a new simplicity to discovering sources of electrical energy waste. Discover when and where energy in your facility is being consumed; from the service entrance to individual circuits. Access and share data remotely with your team via the Fluke Connect app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. \u003cbr\u003e  \u003cbr\u003e Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce your energy cost. \u003cbr\u003e  \u003cbr\u003e - Key measurements: Automatically capture and log voltage, current, power, power factor, energy and associated values \u003cbr\u003e - Fluke Connect compatible: View data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities WiFi infrastructure \u003cbr\u003e - Convenient intrument powering: Power instrument directly from the measured circuit \u003cbr\u003e - Highest safety rating in the industry: 600 V CAT IV\/1000 V CAT III rated for use at the service entrance and downstream \u003cbr\u003e - Measure all three phases: With included 3 flexible current probes \u003cbr\u003e - Comprehensive logging: More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis \u003cbr\u003e - Optimized user interface: B14Quick, guided, graphical setup ensures you re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty \u003cbr\u003e - Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display * Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function \u003cbr\u003e - Complete in-the-field\" setup through the front panel or Fluke Connect: No need to return to the workshop for download and setup or to take a computer to the electrical panel \u003cbr\u003e - Fully integrated logging: Connect other Fluke Connect devices to the Fluke 1734 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module* \u003cbr\u003e - Energy Analyze Plus application software: Download and analyze every detail of energy consumption with our automated reporting \u003cbr\u003e  \u003cbr\u003e Specifications \u003cbr\u003e Accuracy \u003cbr\u003e Parameter\tRange\tResolution\tIntrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) \u003cbr\u003e Voltage\t1000 V\t0.1 V\t±(0.2% + 0.01%) \u003cbr\u003e Current: Direct input\ti17xx-flex 1500 12\"\t150 A\t0.1 A\t±(1% + 0.02%) \u003cbr\u003e 1500 A\t1 A\t±(1% + 0.02%) \u003cbr\u003e i17xx-flex 3000 24\"\t300 A\t1 A\t±(1% + 0.03%) \u003cbr\u003e 3000 A\t10 A\t±(1% + 0.03%) \u003cbr\u003e i17xx-flex 6000 36\"\t600 A\t1 A\t±(1.5% + 0.03%) \u003cbr\u003e 6000 A\t10 A\t±(1.5% + 0.03%) \u003cbr\u003e i40s-EL clamp\t4 A\t1 mA\t±(0.7% + 0.02%) \u003cbr\u003e 40 A\t10 mA\t±(0.7% + 0.02%) \u003cbr\u003e Frequency\t42.5 Hz to 69 Hz\t0.01 Hz\t±(0.1%) \u003cbr\u003e Auxillary input\t±10 V dc\t0.1 mV\t±(0.2% + 0.02%) \u003cbr\u003e Voltage min\/max\t1000 V\t0.1 V\t±(1% + 0.1%) \u003cbr\u003e Current min\/max\tDefined by accessory\tDefined by accessory\t±(5% + 0.2%) \u003cbr\u003e THD on voltage\t1000%\t0.1%\t±0.5 \u003cbr\u003e THD on current\t1000%\t0.1%\t±0.5 \u003cbr\u003e Intrinsic Uncertainty ±(% of reading +% of range)¹ \u003cbr\u003e Parameter\tInfluence quantity\tiFlex1500-12\tiFlex3000-24\tiFlex6000-36\ti40S-EL \u003cbr\u003e 150 A \/ 1500 A\t300 A \/ 3000 A\t600 A \/ 6000 A\t4 A \/ 40 A \u003cbr\u003e Active Power P\tPF 0.99\t1.2% + 0.005%\t1.2% + 0.0075%\t1.7% + 0.0075%\t1.2% + 0.005% \u003cbr\u003e Active Energy Ea\tPF 0.99\t1.2% + 0.005%\t1.2% + 0.0075%\t1.7% + 0.0075%\t1.2% + 0.005% \u003cbr\u003e Apparent power S\t0 PF 1\t1.2% + 0.005%\t1.2% + 0.0075%\t1.7% + 0.0075%\t1.2% + 0.005% \u003cbr\u003e Apparent Energy Eap\t0 PF 1\t1.2% + 0.005%\t1.2% + 0.0075%\t1.7% + 0.0075%\t1.2% + 0.005% \u003cbr\u003e Reactive power Q\t0 PF 1\t2.5% of measured apparent power \u003cbr\u003e Reactive Energy Er\t0 PF 1\t2.5% of measured apparent power \u003cbr\u003e Power Factor PF\t-\t±0.025 \u003cbr\u003e Displacement Power Factor\t-\t±0.025 \u003cbr\u003e DBF\/cos\t-\t±0.025 \u003cbr\u003e Additional uncertainty in% of range¹\tVP-N\u0026gt;250 V\t0.015%\t0.0225%\t0.0225%\t0.015% \u003cbr\u003e ¹Range = 1000 V x Irange \u003cbr\u003e Reference conditions: \u003cbr\u003e - Environmental: 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH \u003cbr\u003e - Input conditions: Cos \/PF=1, Sinusoidal signal f=50 Hz\/60 Hz, power supply 120 V\/230 V ±10%. \u003cbr\u003e - Current and power specifications: Input voltage 1 ph: 120 V\/230 V or 3 ph wye\/delta: 230 V\/400 V Input current: I \u0026gt; 10% of Irange \u003cbr\u003e - Primary conductor of clamps or Rogowski coil in center position \u003cbr\u003e - Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C \u003cbr\u003e  \u003cbr\u003e Electrical Specifications \u003cbr\u003e Power Supply \u003cbr\u003e Voltage range\t100 V to 500 V using safety plug input when powering from the measurement circuit \u003cbr\u003e 100 V to 240 V using standard power cord (IEC 60320 C7) \u003cbr\u003e Power consumption\tMaximum 50 VA (max. 15 VA when powered using IEC 60320 input) \u003cbr\u003e Efficiency\t68.2% (in accordance with energy efficiency regulations) \u003cbr\u003e Maximum no-load consumption \u003cbr\u003e Mains power frequency\t50\/60 Hz ±15% \u003cbr\u003e Battery\tLi-ion 3.7 V, 9.25 Wh, customer-replaceable \u003cbr\u003e On-battery runtime\tFour hours in standard operating mode, up to 5.5 hours in power saving mode \u003cbr\u003e Charging time \u003cbr\u003e Data Acquisition \u003cbr\u003e Resolution\t16-bit synchronous sampling \u003cbr\u003e Sampling frequency\t10.24 kHz at 50\/60 Hz, synchronized to mains frequency \u003cbr\u003e Input signal frequency\t50\/60 Hz (42.5 to 69 Hz) \u003cbr\u003e Circuit types\t1- , 1- IT, Split phase, 3- delta, 3- wye, 3- wye IT, 3- wye balanced, 3- Aron\/Blondel (2-element delta), 3- delta open leg, Currents only (load studies) \u003cbr\u003e Data storage\tInternal flash memory (not user replaceable) \u003cbr\u003e Memory size\tTypical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹ \u003cbr\u003e ¹The number of possible logging sessions and logging period depends on user requirements. \u003cbr\u003e Basic Interval \u003cbr\u003e Measured parameters\tVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy \u003cbr\u003e Averaging interval\tUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min \u003cbr\u003e Averaging time min\/max values\tVoltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms \u003cbr\u003e Demand Interval (Energy Meter Mode) \u003cbr\u003e Measured parameters\tEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy \u003cbr\u003e Interval\tUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off \u003cbr\u003e Standards Compliance \u003cbr\u003e Power\tIEEE 1459 \u003cbr\u003e Interfaces \u003cbr\u003e USB-A\tFile transfer via USB flash drive, firmware updates \u003cbr\u003e Max. current: 120 mA \u003cbr\u003e WiFi\tFile transfer and remote control via direct connection or WiFi infrastructure \u003cbr\u003e Bluetooth\tRead auxiliary measurement data from Fluke Connect 3000 series modules (requires 1734, or 1732 upgrade option) \u003cbr\u003e USB-mini\tData download device to PC \u003cbr\u003e Voltage Inputs \u003cbr\u003e Number of inputs\t4 (3 phases and neutral) \u003cbr\u003e Maximum input voltage\t1000 Vrms, CF 1.7 \u003cbr\u003e Input impedance\t10 M \u003cbr\u003e Bandwidth (-3 dB)\t42.5 Hz - 3.5 kHz \u003cbr\u003e Scaling\t1:1 and variable \u003cbr\u003e Measurement category\t1000 V CAT III\/600 V CAT IV \u003cbr\u003e Current Inputs \u003cbr\u003e Number of inputs\t3, mode selected automatically for attached sensor \u003cbr\u003e Input voltage\tClamp input: 500 mVrms\/50 mVrms; CF 2.8 \u003cbr\u003e Rogowski coil input\t150 mVrms\/15 mVrms at 50 Hz, 180 mVrms\/18 mVrms at 60 Hz; CF 4; all at nominal probe range \u003cbr\u003e Range\t1 A to 150 A\/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12\" \u003cbr\u003e 3 A to 300 A\/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24\" \u003cbr\u003e 6 A to 600 A\/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36\" \u003cbr\u003e 40 mA to 4 A\/0.4 A to 40 A with 40 A clamp i40s-EL \u003cbr\u003e Bandwidth (-3 dB)\t42.5 Hz - 3.5 kHz \u003cbr\u003e Scaling\t1:1 and variable \u003cbr\u003e Auxiliary Inputs \u003cbr\u003e Number of inputs\t2 \u003cbr\u003e Input range\t0 to ±10 V dc, 1reading\/s \u003cbr\u003e Scale factor (available 2014)\tFormat: mx + b (gain and offset) user configurable \u003cbr\u003e Displayed units (available 2014)\tUser configurable (7 characters, for example, °C, psi, or m\/s) \u003cbr\u003e Wireless Connection \u003cbr\u003e Number of inputs\t2 \u003cbr\u003e Supported modules\tFluke Connect 3000 series \u003cbr\u003e Acquisition\t1 reading\/s \u003cbr\u003e Environmental Specifications \u003cbr\u003e Operating temperature\t-10 °C to +50 °C (14 °F to 122 °F) \u003cbr\u003e Storage temperature\t-20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) \u003cbr\u003e Operating humidity\t10 °C to 30 °C (50 °F to 86 °F) max. 95% RH \u003cbr\u003e 30 °C to 40 °C (86 °F to 104 °F) max. 75% RH \u003cbr\u003e 40 °C to 50 °C (104 °F to 122 °F) max. 45% RH \u003cbr\u003e Operating altitude\t2000 m (up to 4000 m derate to 1000 V CAT II\/600 V CAT III\/300 V CAT IV) \u003cbr\u003e Storage altitude\t12,000m \u003cbr\u003e Enclosure\tIP50 in accordance with EN60529 \u003cbr\u003e Vibration\tMIL-T-28800E, Type 3, Class III, Style B \u003cbr\u003e Safety\tIEC 61010-1 \u003cbr\u003e IEC Mains Input: Overvoltage Category II, Pollution Degree 2 \u003cbr\u003e Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 \u003cbr\u003e IEC 61010-2-031: CAT IV 600 V \/ CAT III 1000 V \u003cbr\u003e Electromagnetic compatibility\tEN 61326-1: Industrial CISPR 11: Group 1, Class A \u003cbr\u003e Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) \u003cbr\u003e USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 \u003cbr\u003e Temperature coefficient\t0.1 x accuracy specification\/°C \u003cbr\u003e General Specifications \u003cbr\u003e Color LCD display\t4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel \u003cbr\u003e Warranty\tInstrument and power supply: Two-years (battery not included) \u003cbr\u003e Accessories: one-year \u003cbr\u003e Calibration cycle: two-years \u003cbr\u003e Dimensions\tInstrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in) \u003cbr\u003e Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in) \u003cbr\u003e Instrument with power supply attached: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in) \u003cbr\u003e Weight\tInstrument: 1.1 kg (2.5 lb) \u003cbr\u003e Power supply: 400 g (0.9 lb) \u003cbr\u003e Tamper protection\tKensington lock slot \u003cbr\u003e i17xx-flex 1500 12\" Flexible Current Probe Specifications \u003cbr\u003e Measuring range\t1 to 150 A ac\/10 to 1500 A ac \u003cbr\u003e Nondestructive current\t100 kA (50\/60 Hz) \u003cbr\u003e Intrinsic error at reference condition*\t±0.7% of reading \u003cbr\u003e Accuracy 173x + iFlex\t±(1% of reading + 0.02% of range) \u003cbr\u003e Temperature coefficient over operating temperature range\t0.05% of reading\/°C 0.09% of reading\/°F \u003cbr\u003e Working voltage\t1000 V CAT III, 600 V CAT IV \u003cbr\u003e Probe cable length\t305 mm (12 in) \u003cbr\u003e Probe cable diameter\t7.5 mm (0.3 in) \u003cbr\u003e Minimum bending radius\t38 mm (1.5 in) \u003cbr\u003e Output cable length\t2 m (6.6 ft) \u003cbr\u003e Weight\t115 g \u003cbr\u003e Probe cable material\tTPR \u003cbr\u003e Coupling material\tPOM + ABS\/PC \u003cbr\u003e Output cable\tTPR\/PVC \u003cbr\u003e Operating temperature\t-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) \u003cbr\u003e Temperature, non-operating\t-40 °C to +80 °C (-40 °F to 176 °F) \u003cbr\u003e Relative humidity, operating\t15% to 85% non-condensing \u003cbr\u003e IP rating\tIEC 60529:IP50 \u003cbr\u003e Warranty\tOne-year \u003cbr\u003e * Reference condition: \u003cbr\u003e - Environmental: 23 °C ±5 °C, no external electrical\/magnetic field, RH 65% \u003cbr\u003e - Primary conductor in center position\u003c\/p\u003e\u003c\/div\u003e\r\n\r\n\u003cp\u003e\u003c\/p\u003e\n\u003cul class=\"specs\"\u003e\n\u003cli\u003ePart No: FLU1734EUS\u003c\/li\u003e\n\u003cli\u003eBarcode: 95969801980\u003c\/li\u003e\n\u003cli\u003eBrand: Fluke\u003c\/li\u003e\n\u003c\/ul\u003e\r\n\r\n\r\n\u003c\/body\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":46565104746708,"sku":null,"price":10116.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0490\/2295\/9772\/files\/FLUKE_1732_and_1734__5fa0b6ddc711c8d22ce52d41d89a9050.jpg?v=1753534533","url":"https:\/\/www.dealfirst.com.au\/products\/fluke-1732-and-1734-three-phase-electrical-energy-loggers-advanced-flu1734eus","provider":"DEAL FIRST","version":"1.0","type":"link"}